This article is about a unique approach to custom home design involving fire safety for a home elevator.
Sure did surprise this custom home designer: Home elevator design seems not to involve a shred of home fire safety code to be had across the fruited plain far as he can tell. (Now, there is a U. S. elevator code in the form of ASME A17.1 Safety Code for Elevators and Escalators, which addresses essential safety concerns, e.g., access, switching, guardrails, and such but not home fire safety.)
A home elevator design inherently includes a shaft, or hoistway, that could make a swell chimney, and double the peril by holding within the cab those who could be the most physically vulnerable folks in the house.

Much codified ado is made of home fire safety in regard to residential fire-blocking, but nothing specific about home fire safety in home elevator design that the author can reckon about the potentially airflow-permissive [read: smoke and flame flow-permissive] elevator shaft. (Fire safety regarding vertical shaft enclosures gets some considered attention, e.g., IBC 2000 707.1ff, but not "...for openings totally within an individual dwelling unit and connecting four stories or less." IBC 2000, 707.2, Exception 1.)

In regard to home elevator design and home elevator construction, what's at stake here is fire-degraded wood stud walls and wood ceiling joists collapsing within a hoistway, or shaft, engaging cab and contents, including human contents, in smoke and fire.

Home Fire Safety - Home Elevator Design, Fire Safety Guidelines

A home elevator shaft, or hoistway shall be framed with lightweight, or cold-formed, steel - not wood, where exterior surfaces are available for wallboard application, exterior walls. It shall be finished with not less than 1 layer-5/8" Type-X gypsum wallboard glued, screwed and taped and shall be mudded not less than 3 coats, paying particular attention to screw pocks which shall be taped, too.

The interior wall surface shall be finished with not less than 2 layers-5/8" Type-X gypsum wallboard glued, screwed, and taped and shall be mudded not less than 3 coats, paying particular attention to screw pocks which shall be taped, too.

NOTE: Remember to adjust the home elevator system's manufacturer's shaft framing dimensions to accommodate thicker interior clad; advise the elevator system manufacturer (and your local Fire Marshal) of your specific intentions in regard to home fire safety methods and materials early-on.

The shaft ceiling shall be framed and sheathed on exterior and interior as the walls (see above). It shall be enclosed by not less than 1 door at each stop, which door shall be not less than 1-hour fire-rated, self-closing, shall be self-latching, and smoke-sealing.

Within the cab and outside the door at each stop, a smoke detector shall be applied according to manufacturer instruction, shall be permanently connected to each other overall throughout the residence such that when one or more alarm, all alarm throughout the entire house.

Each alarm shall run on both permanent 120V and replaceable battery, shall feature a combination of ionization and photoelectric sensors, shall not disconnect by wall switch, and shall be connected to a 120V line as first load on a frequently used lighting circuit with overcurrent protection at the panelboard suitable for a double tap.

Within the cab, there shall be not less than 1 dry-chemical, portable fire extinguisher rated not less than 2A:10B:C mounted at 3'-6" above finish floor level to carrying handle.

At each stop, a hallway or other space to which there is direct access from the cab shall have passage within line of sight at two linear feet outside the cab door on-center to not less than two means of emergency egress, not more than one of which means may be an emergency egress window.

Comment: Please note that an electrical box attached to steel frame shall be metal and grounded to Code.

Comment: In sum, the steel's there to break down more slowly when engaged, proposedly to wrack and sag but not to cinders and ash; the tight sealing is intended to counter smoke intrusion; the extra layers of Type-X are there to better hold its form and hold flames from you on your travel through the hoistway.



Article Source: http://www.eArticlesOnline.com

About the Author:
Before The Architect designs and drafts custom home plans nationwide. Its principals Ralph and Jean Pressel have worked hands-on together since the '60s in custom home design, drafting, consulting, plus building and repair in every major trade. The e-book Home Design Standards - Home Building Standards and the website http://www.beforethearchitect.com are enterprises of Before The Architect's principals.


Tags: , ,

Please Rate this Article

 

Not yet Rated

Click the XML Icon Above to Receive Home-and-Family Articles Via RSS!

Recent Related Articles From Home-and-Family

  • Home Fire Safety - Interior Stairway Design Fire Safety Guidelines
    By: Ralph Pressel | Jun 21st 2007
    This article is about custom home designing fire safety in an interior stairway. Read

  • Who Is Responsible For Fire Safety?
    By: Alex Stacey | Aug 21st 2008
    If you are operating a small business, one of your biggest safety concerns is probably a fire. Fire safety precautions are easy to implement and should not be overlooked. Laws have changed over the last 5 years, make sure you are up to date with the new guidelines. Read

  • Tips To Prevent Fire From Occurring In The Workplace Or Home
    By: Freddy Flame | Sep 6th 2007
    Fire Safety advice on how to prevent a fire from occuring either in the home or in the workplace. Read

  • How To Use Fire Extinguishers
    By: Alex Stacey | Aug 21st 2008
    Fire safety is a major concern everywhere. Fire Extinguishers are everywhere and it is unusual that so many people do not know how to use one. Read

  • How To Avoid Fire Damage - Safety Is The Best Precaution To Prevent It
    By: Beth Olignerf | Nov 16th 2008
    There are many steps that one should follow in order to avoid fire damage. This article would take you through some of the important tips which would help an individual in avoiding fire damage. You must be very anxious to know that how you can actually avoid fire damage, but it is recommended that you take the help of profe ... Read

  • Fire Risk Assessment And The Role Of The Responsible Person
    By: Nemco Utilities | May 11th 2010
    Fire costs UK business millions of pounds, from disruption to and loss of business, property damage, fines, compensation claims and increasing insurance premiums. In addition there is the human cost when people die or are seriously injured by fires that occur at work. Read

  • Strategic Fire Protection
    By: Freddy Flame | Sep 3rd 2007
    An overview of modern Business Fire safety principles including fire doors, fire design and automatic fire detection Read

  • Fire Safety Measures And Risk Assessment For Business
    By: Freddy Flame | Sep 6th 2007
    An overview of current fire safety legislation including the role of Risk Assessments for Businesses Read

  • Fire And Home Safety. Test Your Fire And Home Safety Knowledge
    By: Ralph Winn | Sep 23rd 2006
    How much do you know about fires and home safety? Where is the safest air in your home during a fire? What is the proper home safety protocol for a fire? Take this short, six-question quiz to find out the answers to these questions and to test your knowledge of fire and home safety issues. After completing the questions scr ... Read

  • The Importance Of Carrying Out Fire Drills In Your Business
    By: Freddy Flame | Aug 13th 2007
    To ensure your business complies with current fire safety legislation it is imortant to carry out a regular fire risk assessment and carry out regular fire evacuation drills to ensure everyone knows what to do in the event of a fire. Read


Copyright © 2005-2011 eArticlesOnline, LLC - All Rights Reserved
Terms of Service | Privacy Policy